Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Quick Details:
|
12.1"Color TFT LCD Screen, (touch screen for option)
|
Plug-in rechargeable battery,AC/DC available
|
Standard parameters: Standard parameters of ECG, RESP, NIBP SPO2. TEMP,PR/HR.
|
Multiple language: Chinese,English,Spanish,Portuguese,Russian,French,German,Czech,Denish,Dutch,finland,Italian,
Polish, Turkish,Taiwan Trad, Romania
|
Two weeks data storage,1000 alarm events,8 hours wave storage
|
ST and 13 kinds arrhythmia analysis, pacemaker analysis, drug dose calculation
|
Standard Configuration
|
|
Option Configuration
|
|
Main machine
|
1 Set
|
Touch screen function
|
|
ECG lead wire
|
1 PC
|
IBP,EtCO2,
|
|
SPO2 sensor
|
1 PC
|
Printer,CMS,
|
|
BP cuff
|
Vet with different size
|
Suntech Blood Pressure
|
|
SPO2 extension cord
|
1 PC
|
SPO2
|
|
BP extension cord
|
1 PC
|
Dual-channel TEMP
|
|
Power cord
|
1 PC
|
Anesthesia gas module
|
|
Temperature probe
|
1 PC
|
Trolley, Wall mount
|
|
User Manual
|
1 PC
|
|
ECG
|
SPO2
|
NIBP
|
Lead Mode 3-lead and 5-lead are optional
Lead Selection (1,II, II, AVR, AVL, AVF,V) |
Measuring Range: 0 ~ 100%
|
Method: Oscillometry
|
Gain: 2.5mm/mV, ´5.0mm/mV, 10mm/mV, ´20mm/mV
|
Resolution: 1%
|
Measure mode: Manual, Auto, STAT
|
Heart Rate: 15-300 BPM (Adult);
15-350 BPM (Neonatal)
Resolution: 1 BPM Accuracy: ±1% Sensitivity >200 uV(Peak to peak) |
Accuracy: 70% ~ 100% (±2 %)
|
Measure Intervalin AUTO Mode:1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
|
Differential Input Impedance> 5 MQ CMRR
Diagnostic Mode>90 dB Monitor Mode>110 dB Surgery Mode>110 dB Offset Potential:± 300mV Leakage Leakage Current<10μA Pace Pulse Detect: Range:±2±700mV Width:0.12ms Rise Time:10100us Pace Pulse Rejection: Range:±2±700mV Width:0.12ms Rise Time:10100us Baseline Recovery< 3 s After defibrillation. Calibration Signal:1 mVp-p,±5% accuracy ST measurement: Range:-2.0+2.0 mV Accuracy:-0.8mV~+0.8mV:±0.02mVor±10%,which is greater Other Range: unspecified
Arrhythmia:13 Types: ASYSTOLE,VFIB/VTAC,COUTPLET,BIGMINY,TRIGEMINY,RONT,VT>2,BRADY, MISSED BEATS, PNP,PNC
|
Pulse Rate: Measure and Alarm Range:20~250bpm
|
Measure Period in STAT Mode:5 min Pulse Rate
Range:40240 bpm Measure and Alarm Range:Adult ModeSYS:40280 mmHg DIA:10220 mmHg MEAN:20240 mmHg Pediatric Mode: SYS:40220 mmHg DIA:10160 mmHg
MEAN:20170 mmHg
Neonatal Mode:SYS:35135 mmHg DIA:10100 mmHg MEAN:20110 mmHg Staticpressure accuracy:±3mmHg Error:± 5mmHg Maximum Standard Deviation:8mmHg Overpressure Protection:Adult:300 mmHg Pediatric;240 mmHg Neonatal:150 mmHg |
ECG Signal Range:±5mv(Vp-p)
Surgery:120 Hz
Monitor:0.540 Hz
Diagnostic: 0.05130 Hz
|
Resolution: 1 BPM
|
Resolution: 1mmHg
|
|
Accuracy: ±3 BPM
|
Accuracy:Maximum Mean
|
Respiration
|
Pulse Rate(PR)
|
TEMP
|
Method:Impedance between RA-LL or RA-LA
|
Measurement range:25 to 240 bpm
|
Channel:2
|
Differential Input Impedance>2.5 M2 Respiration
|
Refreshing rate:1s
|
Measure and Alarm Range:050
|
Impedance Range:0.3~3Q Base Impedance
|
Updated period:8s,16 s
|
|
Range:200Q-20000Ω Bandwidth:0.32 Hz
Gain:x0.25,x0.500,x1,x2,x4 Respiration Rate: Measurement Range: Adult:0 120 BrPM Neonatal/Pediatric:0150 BrPM Resolution:1 BrPM Accuracy:0~6 BrPM: unspecified 7~150 BrPM:±2BrPM or±2%,use the greater Inspiriting current:< 300 μA RMS max Apnea Alarm:1040 s |
± 5 bpm(measured with motion)
Low Perfusion:
Conditions:Pulse
mplitude:>0.02% Light penetration:>5% SpO2 accuracy:± 2% PR accuracy:±3 bpm |
Accuracy(no sensor):±0.1(25-45),±0.2(other)
Accuracy(include sensor):±0.2(32- 42)±0.3(other) |
Resolution:1 BrPM
|
Resolution:1bpm
|
Resolution:0.1
|
Accuracy:0~6 BrPM: unspecified
|
Accuracy:±3 bpm(measured without motion)
|
Accuracy(no sensor):±0.1(25-45),±0.2(other)
Accuracy(include sensor):±0.2(32- 42)±0.3(other) |