Model
|
K-DI02 Digital infusion pump
|
Screen
|
Display with double screen to make remote observation possible
|
Battery
|
Three options for power supply:
First: 100~ 240VAC, 50/60Hz; Second: Inserted Li battery 11.1V, capacity2 1800mAh; 4 hours backup;time at the rate of 25ml/h for a fully charged battery; Third: External DC 12V power supply. |
Dimension
|
140 mm(L) 128 mm(W) 228 mm(H)
|
Infusion Mode
|
d/min mode;mI/h mode;Vol/T mode
|
Pumping Way
|
Peristaltic fingers
|
Drug Library
|
Up to 1000 drugs are provided(K-DI02A only)
|
FF Rate
|
100 ~ 1200ml/h(100ml/step)
|
History Records
|
Up to 2000pcs records, including operation, alarm and modification; Trackable treatments are ensured.
|
Dual CPU
|
Safety are guaranteed by dual CPU design.
|
Infusion Accuracy
|
d/min mode: S +3% (after calibration) ml/h mode: S5% (after calibration)
|
Alarm
|
Near infusion finished, infusion finished, door open, air bubble, forgotten operation, battery low, battery empty, abnormal
running state, equipment failure, power fault, replace infusion set, drop sensor is pulled out, etc. |
Infusion Rate
|
ml/h mode: 1 ~ 1200ml/h d/min mode:1 ~ 266 d/min
|
KVO Rate
|
1 ~ 5.0ml/h
|
KVO Rate
|
1 ~ 5.0ml/h
|
VTBI (volume to be Injected)
|
1 ~ 9999ml
|
Cumulative Infusion Volume
|
0~ 9999.9ml
|
Air Bubble size
|
≤25μl
|
Keypad
|
Numeric keypad, user friendly
|
BOLUS
|
Automatically release tubing pressure when there is occlusion.
|
Self-Testing
|
System self-test is completed as turning on, which ensures safe work;
|
Lower noise
|
Lower noise and less vibration are supported by application of motor driver IC imported from German and motor imported from Japan.
|
Drop sensor(Optional)
|
Remotely control infusion processes to realize safer and precise infusion.
|
Pressure Monitoring
|
3 Levels of occlusion pressure are available(high/medium/low).
|
Voice Alarm System
|
Exclusive technology to fulfll combination of human voice, legible words and lights.
|
d/min mode
|
Set rate of d/min to conduct infusion(1-266d/min)
|
mI/h mode
|
Set rate at ml/h to conduct infusion(1-1200ml/h)
|
VoI/T mode
|
Automatically calculate rate by setting time and volume (1-9999ml)
|
Certification
|
Certified by TUV Rheinland and EN ISO13485: 2016
|